DHCOM PXA270-D2: Difference between revisions

From Wiki-DB
Jump to navigationJump to search
Ageisreiter (talk | contribs)
Created page with "== FAQ List == 1. The Core Module don't restart, after the supply voltage is disconnected and connected again. Reason: This problem appears, if a active USB Hub is connected..."
 
Christoph (talk | contribs)
No edit summary
Line 1: Line 1:
[[Image:COMPXA270.png|600px|COM AM35-D2]]
== FAQ List ==
== FAQ List ==
  1. The Core Module don't restart, after the supply voltage is disconnected and connected again.
  1. The Core Module don't restart, after the supply voltage is disconnected and connected again.
     Reason: This problem appears, if a active USB Hub is connected to the device.  
     Reason: This problem appears, if a active USB Hub is connected to the device.  
     Workaround: Ensure, that the USB Hub voltage will also be interrupted if the supply voltage of the core module is disconnected.
     Workaround: Ensure, that the USB Hub voltage will also be interrupted if the supply voltage of the core module is disconnected.

Revision as of 14:09, 6 December 2011

COM AM35-D2

FAQ List

1. The Core Module don't restart, after the supply voltage is disconnected and connected again.
   Reason: This problem appears, if a active USB Hub is connected to the device. 
   Workaround: Ensure, that the USB Hub voltage will also be interrupted if the supply voltage of the core module is disconnected.